4.3.7. Temperature measurement
CAUTION
Before taking temperature measurements in circuit remove power from the
circuit being tested and discharge all capacitors.
Fig. 8: Using the instrument for temperature measurement
1. Switch on °C or °F depend on the kind of measurement
2. Insert the standard adapter accessory into VTempHz%CAP jack (+ polarity), and
COM jack (- polarity) (see Fig. 8)
3. Connect the standard bead type K probe or the optional type K probe (see paragraph
6.3.2) into the adapter with respect the correct positive and negative polarity then
temperature reading is displayed
4. If the message "O.L" is displayed the higher range is reached
5. For HOLD function please refer to paragraph 4.2