Ht-instruments HT9022 Manuel d'utilisateur Page 32

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 31
HT9022
EN - 30
5.5.1.2. DC power
The screen to the side shows an example of DC power
measurement.
Mod Par Sys Fnz
DC
0.40 kW
19/01-17:00:00
5.5.1.2.1. Key F4 “Fnz” in DC Power measurement
While measuring DC Power, press key F4 (Fnz) to open the
drop-down menu shown on the screen to the side. At each
subsequent pressure of key F4, the cursor will scroll through the
available items, as follows:
Max: it constantly displays the maximum value of the
measured parameter;
Min: it constantly displays the minimum value of the
measured parameter;
Rst: it deletes all stored Max and Min values;
Mod Par OK Fnz
DC
0.40 kW
19/01-17:00:00
Esc: it goes back to a normal measuring mode.
By pressing key F3 (OK), the selected item is confirmed.
To the side, an example of measurement with active Max
function. The display shows the active function.
Mod Par Sys Fnz
Max DC
0.40 kW
19/01-17:00:00
5.5.1.3. DC voltage and current
The screen shows an example of DC Voltage and Current
measurement.
Mod Par Sys Fnz
DC
80.0 V
20.0 A
19/01-17:00:00
Max
Min
Rst
Esc
Vue de la page 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 55 56

Commentaires sur ces manuels