QuickLAN 6050
EN - 6
5. SETTINGS
5.1. SETUP SELECTIONS
The setup mode allows to select and calibrate cable characteristics. Once changed, these
settings are stored and remain in the tester even when tester is turned off.
5.1.1. Power–up setup procedure
1. Turn off the tester, press and hold down LENGTH key, then press and hold down
power key, until display show “ ”.
2. Press or key to the desired length units between feet (ft) and meters (m).
3. Press enter key to store the unit (ft/m) and exit this mode.
5.1.2. Selecting a Cable Type Procedure
1. Press SET key to enter setup mode.
2. Press ▼▲key until the desired “cable” type is displayed, then press enter key.
3. Press keys until the desired “category” is displayed, then press enter key.
4. Press ▼▲key until the desired “wire size” is displayed, then press enter key.
5. Press ▼▲key to choose proceeding or not the “ ” function, then press enter key.
6. Press ▼▲key until the desired “ ” is enable or disable, then press enter key.
7. Press SET key to exit this mode.
Note: By pushing SET key in any moment it will exit setup mode.