6.3. WIRE MAP CHECKING
Use the tester wire map function and remote identifier unit (ID), to determine the wiring
status of both the near end and far end of the cable. Wire Map measuring procedure:
1. Select cable type under test.
2. Connect the cable under test to the appropriate connectors on the tester and on the
identifier.
3. Press WIRE MAP key.
Fig. 6: Good cable
Failure Display Wiring Description
Short (near end)
1
3
6
2
1
3
6
2
Alternately display an “s” with
actual wire number of each wire
shorted.
Open
2
6
3
2
6
3
Alternately display “o” with the
number of each open wire.
Miswire
33
2 2
Displays the wiring detected by
the test tool and flash the wire
numbers involved in the
anomaly.
Tab. 2: Wire map failure
6.4. DATA MEMORY AND READ OPERATING
How to store data in the memory:
1. Perform the test.
2. Press MR key each time, LCD shows M and memory location numbers (01 to 99).
How to recall data stored in the memory:
1. Press MR key for 3 seconds to enter the read memory data mode, LCD shows R and
memory location numbers, additional information can be viewed with the key.
2. Press key to scroll through the logged readings.
3. Press MR key again to exit READ mode, LCD will show “Out r EAD”.
How to delete data stored in the memory:
1. Press
key to turn off the meter.
2. Press and hold down MR key then press
key to turn on the meter, until LCD shows
“dEL”, press ▲▼ key to cycle display “YES” or “NO”, select “YES” and press key to
cleared all memory.